裝置檢測正常火災的檢查
Inspection of safety device for detecting normal fire
吹掉正?;穑訜釥t應在45秒內切斷。 溫度限制保護87°C
Blow out the normal fire, the heating furnace should be cut off within 45 seconds. Temperature limit protection 87 ° C
電磁加熱爐的加熱溫度升87°C,主燃燒器將自動熄滅。 當溫度下降約10°C時,加熱爐將自動工作。 電源(檢測)失敗
When the heating temperature of the electromagnetic heating furnace rises to 87 ° C, the main burner will automatically extinguish. When the temperature drops by about 10 ° C, the furnace will operate automatically. Power failure
電磁加熱爐處于工作狀態(tài),加熱爐在供電后自動工作。 過熱保護檢測
The electromagnetic heating furnace is in working state, and the heating furnace works automatically after power supply. Overheat protection detection
拔下過熱保護的上部連接插頭,加熱爐應停止工作。 加熱溫度限制保護
Pull out the upper connecting plug of overheat protection, and the heating furnace should stop working. Heating temperature limit protection
拔下溫度限制保護線,主燃燒器應立即熄滅。 防堵塞檢測
The main burner shall be extinguished immediately after the temperature limit protection wire is pulled out. Anti clogging detection
阻塞煙道,主燃燒器應立即熄滅。
If the flue is blocked, the main burner should be extinguished immediately.
其他檢測加熱循環(huán)中的水壓
Other tests for water pressure in heating cycle

加熱循環(huán)中的水壓應為1.5巴左右,水壓應高于1巴。 衛(wèi)生熱水溫度
The water pressure in the heating cycle should be about 1.5 bar, and the water pressure should be higher than 1 bar. Sanitary hot water temperature
如果衛(wèi)生熱水流量不足,請檢查冷水進水管中的過濾器。 加熱溫度升高
If the sanitary hot water flow is insufficient, check the filter in the cold water inlet pipe. Heating temperature rise
如果溫度上升過快,請檢查旁通閥或回水處過濾器的調節(jié)情況。 膨脹水箱
If the temperature rises too fast, check the adjustment of the bypass valve or the filter at the return water. Expansion tank
當加熱功能運行時,如果加熱循環(huán)水中的水壓上升過快,檢查膨脹水箱的壓力。 在這種情況下,連接板的加熱水出口和回水閥關閉,加熱爐中的水通過加熱排水閥排出,膨脹水箱的壓力應在0.5到0.6巴之間。
When the heating function is running, if the water pressure in the heating circulating water rises too fast, check the pressure of the expansion tank. In this case, the heating water outlet and return valve of the connecting plate are closed, the water in the heating furnace is discharged through the heating drainage valve, and the pressure of the expansion tank should be between 0.5 and 0.6 bar.
檢查衛(wèi)生用水功能,檢查衛(wèi)生用水,加熱爐處于夏季功能位置。
Check the function of sanitary water, and check that the heating furnace is in the functional position in summer.
檢查燃燒器的點火狀況;
Check the ignition condition of burner;
二次檢查衛(wèi)生用水,加熱爐處于冬季功能位置。
The heating furnace is in the functional position in winter.
檢查燃燒器的點火狀況;
Check the ignition condition of burner;
檢查加熱爐的衛(wèi)生水調節(jié)功能; 在低進氣量的條件下運行衛(wèi)生用水功能,檢測氣體量的變化和水溫的變化。
Check the sanitary water regulation function of the heating furnace; operate the sanitary water function under the condition of low air intake to detect the change of gas quantity and water temperature.